996 Carrera Group 0 Part 1 Diagnosis / PAGE 124
1.2 General information on fault memory Open circuit or short to ground: · Fault code setting conditions
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
1.2 General information on fault memory Open circuit or short to ground:
Fault code setting conditions There is (present)or was (not present)a short
circuit to ground or an open circuit in the circuit
Faultcodescan be set in severalcircumstances: to the control moduleterminal.
e.g. Open circuit or short to B+:
There is (present)or was (not present)a short
powerfailure circuit to voltage or an open circuit in the circuit
to the control moduleterminal.
-plug connectionsdisconnected
Short to ground:
-battery disconnected There is (present)or was (not present)a short
circuit to ground in the circuit to the control
etc. moduleterminal.
In these circumstances,no fault is present in Short to B+:
the system and the fault memory must be There is (present)or was (not present)a short
erased. circuit to voltage in the circuit to the control
moduleterminal.
Note:
2. LightonThe fault memory of the PSM control module is
maintainedeven in removed state. PSMlightswitchedon
Fault memory Info key F8 3. Present/ not present
Faultis detected as present or not presentIn order to be able to assess the fault exactly,
the fault memory Info key F8 must be pressed.
This informationshould be saved using the Save
key F4 and printed out. If a fault code is stored
with "not present" status and no other problems
are present, then the fault memory must be
erased.
1. Signalimplausible/ no signalchange/ open
circuitor short to ground/ shortto B+
Signal implausible:
The incoming signal to the control module
deviates from the signal expected.
No signalchange:
Theincomingsignalto the controlmoduledoes
not change.
4503 Diagnosis/troubleshooting PSM 45 -D 61