fullymatted.
Back to search
996 Carrera Group 0 Part 1 Diagnosis / PAGE 145

FC rester display fault text Remedy · 4226 Front right ABS outlet valve

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 145
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

FC rester display fault text Remedy 4226 Front right ABS outlet valve 8.14 .Valve voltage actual value is evaluatedand displaysan implausiblevalue (valve circuit or driver output malfunction) .Short circuit to ground or open circuit in the circuit to control module terminal 55 Effect: .PSM function is switched off .ABS function is switched off .ASR function is switched off Possible cause of fault: .Wire faulty .PSM hydraulic unit faulty Affected terminals: 55 4231 Front right ABS inlet valve 8.15 .Valve voltage actual value is evaluatedand displaysan implausiblevalue (valve icircuit or driver output malfunction) .Short circuit to ground or open circuit in the circuit to control module terminal 26 Effect: .PSM function is switched off .ABS function is switched off .ASR function is switched off Possible cause of fault: .Wire/plug connection faulty .PSM hydraulic unit faulty Affected terminals: 26 45 -D 82