996 Carrera Group 0 Part 1 Diagnosis / PAGE 145
FC rester display fault text Remedy · 4226 Front right ABS outlet valve
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
FC rester display fault text Remedy
4226 Front right ABS outlet valve 8.14
.Valve voltage actual value is evaluatedand displaysan implausiblevalue (valve
circuit or driver output malfunction)
.Short circuit to ground or open circuit in the circuit to control module terminal 55
Effect:
.PSM function is switched off
.ABS function is switched off
.ASR function is switched off
Possible cause of fault:
.Wire faulty
.PSM hydraulic unit faulty
Affected terminals:
55
4231 Front right ABS inlet valve 8.15
.Valve voltage actual value is evaluatedand displaysan implausiblevalue (valve
icircuit or driver output malfunction)
.Short circuit to ground or open circuit in the circuit to control module terminal 26
Effect:
.PSM function is switched off
.ABS function is switched off
.ASR function is switched off
Possible cause of fault:
.Wire/plug connection faulty
.PSM hydraulic unit faulty
Affected terminals:
26
45 -D 82
This is a source reference. Confirm exact model applicability in the original material.