fullymatted.
Back to search
996 Carrera Group 0 Part 1 Diagnosis / PAGE 151

Tester display fault text Remedy · 4440 Steering-angle

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 151
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

Tester display fault text Remedy 4440 Steering-angle sensor 8.27 .Steering-angle sensor actual value is evaluatedand displaysan implausiblevalue .Short circuit to ground or open circuit in the circuit to control moduleterminal 2 Effect: .PSM function is switched off Possible cause of fault: .Steering-angle sensor calibration incorrect .Wiring/plug connection faulty .Steering-angle sensor faulty Affected terminals: 2.61.63 4460 Pressure sensor 8.29 .Pressure sensor actual value is evaluatedand displaysan implausiblevalue .Short circuit to ground/voltage or open circuit in the circuit to control module terminals67, 68, 69 Effect: .PSM function is switched off Possible cause of fault: .Wiring faulty .Pressure sensor faulty (replace booster pump) Affected terminals: 67, 68. 69 4480 Booster pump 18.13 .Booster pump voltage actual value is evaluated and displays an implausible value .Short circuit to ground/voltage or open circuit in the circuit to control module terminals 22, 24, 51 Effect: .PSM function is switched off Possible cause of fault: .Booster pump motor blocked/faulty .Wiring/plug connection faulty Note: Do not jumper the pump; it must not run dry under any circumstances! Affected terminals: 22, 24. 51 45 -D 88~

This is a source reference. Confirm exact model applicability in the original material.