996 Carrera Group 0 Part 1 Diagnosis / PAGE 156

FC display fault text Remed · 5504 Extraordinary operating condition

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 156
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

911 Carrera 4 (996) PSM diagnosis FC display fault text Remed 5504 Extraordinary operating condition Erase .The fault is stored if the PSM control module is in control for longer than 60 s. fault (Extremedriving situation: snow-coveredcircular paths, icy roads, constant braking) memory Effect: .PSM function is switched off .ABS function is switched off " ASR function is switched off! Possible cause of fault:'. Vehicle was in an extraordinaryoperating condition Affected terminals: 5520 CAN data bus (drive) See DME .Engine running diagnosis .DME control module transmits incorrect signal Effect: .PSM function is switched off .ABS function is switched off .ASR function is switched off Possible cause of fault: .Fault in DME control module Affected terminals: 5521 Incorrect data exchange See DME .Engine running diagnosis .DME communication incorrect Effect: .PSM function is switched off Possible cause of fault: .Fault in the DME Affected terminals: ,61.63 45 -D 93 J~er