996 Carrera Group 0 Part 1 Diagnosis / PAGE 194
Test Work instruction Result Possible causes of fault · TO3 voltage short / open circuit in G
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
Test Work instruction Result Possible causes of fault
TO3 voltage short / open circuit in Greater
signal circuit than 11 V -Short circuit to voltage/
open circuit in circuit between:
.Ignition on Relayfor solenoid valves socket
.Measure voltage betweenthe terminal 6
following terminals: and
Relayfor solenoidvalves socket PSMcontrol module
terminal 4 wiring harnessplug (wiring harness side)
and terminal 37
relay for solenoid valves socket or
terminal 6 Yes:104 -PSM control module faulty
Test: short to ground/ Greater No:
open circuit in power supply circuit than 11 V -Short circuit to ground/
open circuit in circuit between:
.Measure voltage betweenthe fuse E9 output-side contact
following terminals: and
Relayfor solenoid valves socket relay for solenoid valves socket
terminal 2 terminal 2
and
ground Note: The plug connection X 1/3
(terminal 2) is located in the wiring
harness. Check the wiring harness for
Yes: 105 pinching or chafing damage.
45 -D 131
II:T04Test:INo:
This is a source reference. Confirm exact model applicability in the original material.