996 Carrera Group 0 Part 1 Diagnosis / PAGE 272
Tester disDlav fault text Remed · Hydraulic control unit faulty
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
Tester disDlav fault text Remed
Hydraulic control unit faulty Replace
Front right outlet valve voltage actual value is evaluatedand shows implausible hydraulic
value (valve circuit or driver output malfunction) unit
Effect:I
PSM function is switched off:
ABS function is switched offI
ASR function is switched off
Possible cause of fault:
PSM hydraulic unit faulty
Affected terminals:
4231 Hydraulic control unit faulty Replace
.Front right inlet valve voltage actual value is evaluatedand shows implausiblevalue hydraulic
(valve circuit or driver output malfunction) unit
Effect:
.PSM function is switched off
.ABS function is switched off
.ASR function is switched off
Possible cause of fault:
.PSM hydraulic unit faulty
Affected terminals:
4236 Hydraulic control unit faulty Replace
Front left outlet valve voltage actual value is evaluatedand shows implausible hydraulic
value (valve circuit or driver output malfunction) unit
Effect:
PSM function is switched off
ABS function is switched off
ASR function is switched off
IPossible cause of fault:I
PSM hydraulic unit faulty
Affected terminals:
~ 45 -D 209