996 Carrera Group 0 Part 1 Diagnosis / PAGE 280
IFC ITester display fault text
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
911 Carrera (996) PSM diagnosis
IFC ITester display fault text I RemedyI
5265 Switch-over valve 1 Replace
Switch-overvalve voltage actual value is evaluatedand shows implausiblevalue hydraulic
(valve circuit or driver output malfunction) unit
Effect:
: PSM function is switched off
ABS function is switched off
ASR function is switched off
Possible cause of fault:
Wiring/plug connection faulty
PSM hydraulic unit faulty
Affected terminals:
5267 ISwitch-over valve 2 Replace
Switch-overvalve voltage actual value is evaluatedand shows implausiblevalue hydraulic
(valve circuit or driver output malfunction) unit
Effect:
PSM function is switched off
ABS function is switched off
ASR function is switched off
)ossible cause of fault:
Wiring/plug connection faultyI
PSM hydraulic unit faultyIAffected
terminals:
45 -D 217