996 Carrera Group 0 Part 1 Diagnosis / PAGE 282
FC Tester display fault text Remed · Extraordinary operating condition
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
911 Carrera (996) PSM diagnosis
FC Tester display fault text Remed
Extraordinary operating condition Delete
.The fault is stored if a control operation lasts for longer than 60 s. (Extreme fault
driving situation: snow-<:overedcircular paths, icy roads, constant braking) memory
Effect: and
.PSM function is switched off carry out
.ABS function is switched off test drive
.ASR function is switched off
Possible cause of fault:
.Vehicle was in an extraordinaryoperating condition
Affected terminals:
5505 Electrical system (steering-angle sensor) 8.16
.Ignition on
.The fault is stored if the electrical system of the steering-anglesensor is faulty
Effect:
.PSM function is switched off
.ABS function is switched off
.ASR function is switched off
Possible cause of fault:
.Wiring faulty
.Steering-angle sensor faulty
Affected terminals:
21,39
5506 Rate-of-turn sensor, electrical system 8.17
Ignition on
I-The fault is stored if the electrical system of the rate-of-tumsensor is faulty
Effect:
PSM function is switched off
ASS function is switched off
ASR function is switched off
Possible cause of fault:
Wiring faulty
Rate-of-turnsensor faulty
iAffected terminals:
i9 10 21 39 40
45 -D 219
I
This is a source reference. Confirm exact model applicability in the original material.