996 Carrera Group 0 Part 2 Diagnosis / PAGE 29
General instructions · The airbag system is constantly monitored by a The following components must be removed and
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
911 Carrera (996) Airbag diagnosis
General instructions
The airbag system is constantly monitored by a The following components must be removed and
diagnosis unit in the triggering unit. Any fault is si- replaced following an accident in which the air-
gnalled by a warning light. bag system was triggered:
The warning light for the airbag system lights up
in the event of a fault.
Contact unit The airbag warning light lights for approx.
3 seconds after the ignition is switched on and Triggered airbag unit(s)
goes out if no fault has been entered in the fault
memory. The triggering unit must be replaced after the
airbag is triggered for the third time.
If it lights up again, this indicates a fault in the
system. The fault can be read aut with the Par-
sche System Tester 2.
Note
A period of 10 seconds is required to enablethe
triggering unit to identify all faults in the system.
In order to guarantee that every possible fault
source is checked during the vehicle check, the
ignition must be switched on for at least 10
seconds.
The fault memory must be cleared following
a fault in the airbag system and after it has been
remedied.
The replacement of a component must be noted
in the Guaranteeand Maintenancebooklet. To do
this, attach the documentationnumber in a free
panel intended for that purpose. The documenta-
tion number is attached to the replacementpart
as a sticker.
--
69 01 Diagnosis/troubleshooting, airbag 69 -D 3
Printed in Germany, 1997
99669Dl