996 Carrera Group 0 Part 2 Diagnosis / PAGE 55

Roll-over protection system diagnosis 911 Carrera (996) · 2. The control module 3. Ele

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 55
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

Roll-over protection system diagnosis 911 Carrera (996) 2. The control module 3. Electrical plug connection of the roll-over bar The control module consists of: The plug connectionsare situated on the rear A g-sensor (g = gravitation),which detects side of the roll-overbar. Before connecting and loss of contact with the road surface disconnectingthe plug connection,first unscrew the six fastening screws of the roll-overbars. Two level sensors, which detect the vehicle 4. Warnins light of roll-over inclination,transverse and longitudinal protection system acceleration After the ignition has been switched on, Evaluationelectronics with self-diagnosis the warning light lights up for five seconds In the event of a fault, the warning light briefly Capacitors to provide reserve power goes out and then comes back on continuously. if the battery voltage fails. Note The warning light also lights up if the transport lock has been activated via the diagnostic module. 231_98 1. Level sensors 2. g-sensor 3. Evaluationelectronics 4. Capacitors 69 -D 30 69 71 Diagnosis/troubleshooting, roll-over protection system 99669D23 Printed in Germany -11, 1998

This is a source reference. Confirm exact model applicability in the original material.