996 Carrera Group 0 Part 2 Diagnosis / PAGE 71
General information · The airbag system is constantly monitored by a The following components must be removed
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
911 Carrera (996) Diagnostic airbag
General information
The airbag system is constantly monitored by a The following components must be removed
diagnosis unit in the triggering unit. Any fault is and replaced following an accident in which
signalled by a warning light. the airbag system was triggered:
The warning light for the airbag system lights Contactunit
up in the event of a fault.
Triggered airbag unit(s)
The airbag warning light lights for approx.
3 seconds after the ignition is switched on The triggering unit must be replaced after the
and goes out if no fault has been entered airbag is triggered for the third time.
in the fault memory.
Warning:
If it lights up again, this indicates a fault in Danger of injury
the system. The fault can be read out with
> Observe safety instructionswhenthe Porsche System Tester 2. &
working on the airbag system
(see ServoNo. 69).
Note
A period of 10 seconds is required to enable
the triggering unit to identify all faults in the
system. In order to guarantee that every
possible fault source is checked during the
vehicle test, the ignition must be switched
on for at least 10 seconds.
The fault memory must be cleared following
a fault in the airbag system and after it has
beenremedied.
The replacement of a component must be noted
in the Guaranteeand Maintenancebooklet. To
do this, attach the documentationnumber in
a free panel intended for that purpose. The
documentationnumber is attached to the
replacementpart as a tear-off sticker.
69 01 Diagnosis/troubleshooting, airbag 69 -D 47
Printed in Germany -12, 1998 99669D45
This is a source reference. Confirm exact model applicability in the original material.