996 Carrera Group 0 Part 2 Diagnosis / PAGE 116
Fault, Fault code Possible causes, elimination, notes · Test point 18
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
911 Carrera (996) Seat memory diagnosis
Fault, Fault code Possible causes, elimination, notes
Test point 18
Pot. mirror right horizontal This fault is stored in the following cases:
open circuit 1. There is an open circuit in the wire to the pot. right rearview mirror.
Fault code 20
2. The potentiometer is faulty
3. The control module is faulty.
Elimination
Replacesupport with transmission.
Actuate switch for memory seat adjustment,
The text in the fault memory changesfrom present to not present
if the cause of the fault has really been eliminated.
If the fault is no longer present, erase the fault memory
If the fault is still present, there is a fault in the wire.
For a fault in the wire, proceed as described below:
Disconnectmirror plugfrom the controlmodule.
Disconnectsupport with transmissionplug,
Use an ohmmeter to check for open circuit on the support plug
Pin 5 and the mirror plug on the control module Pin 11.
Ohmmeterdisplay <5.0.
Use an ohmmeter to check for open circuit on the support plug
Pin 7 and the mirror plug on the control module Pin 4.
Ohmmeter display <5,Q
Use an ohmmeter to check for continuityon the support plug
Pin 3 and Pin 5.
If no fault is detected in the wire, replace the control module,
7298 Diagnosis/troubleshooting, seat memory (System SOl) 72 -D 27
Printed in Germany -25, 1999 99672Dl
This is a source reference. Confirm exact model applicability in the original material.