996 Carrera Group 0 Part 2 Diagnosis / PAGE 138
Function, individual components · 1. Heating/air-conditioning unit 1.2 Blower outlet sensor
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
911 Carrera (996) Heating diagnosis
Function, individual components
1. Heating/air-conditioning unit 1.2 Blower outlet sensor
The heatingjair-conditioningunitincludes: The blower outlet sensor measures
the temperature of air emerging
Heat exchanger (to heat the air) into the footwell.
Temperature mixing valve
2. Heating! air-conditioning control
(to control the interior temperature)
Central valve (to control the air flow) The heatingjair-conditioningcontrol includes
the closed and open-loopcontrol electronics,
Outside air / recirculation valve as well as switches for manualinfluence
(to compensate for the dynamic pressure, on automatic program control.
or recirculation control)
The heatingjair-{:onditioningcontrol regulates
Fresh-airblower the different valves according to the set
temperature, the interior temperature,
Outside sensor the outside temperature, the vehicle
(to measure the intake air temperature) speed and the intensity of sunlight
shining into the vehicle.
Blower outlet sensor
(to measure the footwell temperature) 3. Interior sensor
Driver (to control the fresh-air blower speed) The interior sensor measuresthe temperature
of the passengercompartment.
Evaporator (to cool the air)
4. Sun sensor Expansionvalve
The outside air is heated or cooled in Thesunsensormeasuresthe intensity
the heating/air-conditioningunit and of sunlightshininginto the vehicle.
distributed to the air vents.
1.1 Outside sensor
The outside sensor measuresthe temperature
of the incoming air.
80 01 Diagnosis/troubleshooting, heating 80 -D 7
Printed in Germany -11. 1998 99680Dl
This is a source reference. Confirm exact model applicability in the original material.