996 Carrera Group 0 Part 2 Diagnosis / PAGE 147

Fault, Fault code Possible causes, elimination, notes · Test point 1

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 147
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

Fault, Fault code Possible causes, elimination, notes Test point 1 Interface to Diagnosis conditions instrumentcluster No control module fault stored. No fault with supplyvoltage (terminal 15). Open circuit Short to ground Open circuit Fault code 20 1. Unplug connector B from the heating/air-conditioning control, 2. Unplugconnector III from the instrumentcluster. 3. Connectohmmeter to connector B 13 and to connector III pin 26. Display < 5 .Q Note The wire is routed via the 12-pole plug connection on the heating/air-conditioningunit. Short to ground 1. UnplugconnectorB from the heating/air-conditioningcontrol. 2. Unplug connector III from the instrumentcluster. 3. Connectohmmeterto connector B 13 and ground, Display: 00 .0. If a -5 .Q is displayed,check wiring harnessfor pinching and chafing damage. 80 -D 16 80 01 Diagnosis/troubleshooting, heating 99680Dl Printed in Germany. 11, 1998