996 Carrera Group 0 Part 2 Diagnosis / PAGE 159
Fault, Fault code Possible causes, elimination, notes · 6. Unplugthe DME (ECM)connector.
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
Fault, Fault code Possible causes, elimination, notes
6. Unplugthe DME (ECM)connector.
7. Connectohmmeter to D 6 and DME connector pin 69.
Display: < 5 .Q
Note
The wire is routed via two plug connections,
8. Removethe air-conditioningcompressor relay.
9. Connectohmmeter to terminal 85 and DME connector pin 62.
Display: < 5 .Q
Note
The wire is routed via one plug connection.
Test point 12
Motor of fresh-air blower Diagnosisconditions
No control module fault stored.
Voltage too low Supplyvoltage OK.
Voltage too high Nominalblower voltage> 3 volts.
Fault code 31 Nominalblower voltage stabilised.
Voltage too low
Note
Voltage too low means that the measured blower voltage lies
below the nominalblower voltage.
1. Check the heating activation relay.
Battery positive voltage must be present at terminal 87
when the ignition is switchedon.
2. Unplug connector C from the heating/air-conditioningcontrol,
80 -D 28 80 01 Diagnosis/troubleshooting, heating
99680Dl Printed in Germany -11, 1998