996 Carrera Group 0 Part 2 Diagnosis / PAGE 161

Heating diagnosis 911 Carrera (996) · Fault, Fault code Possible causes, elimination, notes

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 161
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

Heating diagnosis 911 Carrera (996) Fault, Fault code Possible causes, elimination, notes Voltage too high Note A higher blower voltage can only be caused by a short to ground on the wires to pins 1 or 2 of the driver. 1. UnplugconnectorC from the heating/air-conditioningcontrol. 2. Unplug connector from the driver, 3. Connectohmmeter to C 16 and ground. Display: 00 .Q 4. Unplug connector from the fan motor. 5. Connectohmmeter to driver connector pin 2 and ground. Display: 00 .0. Test point 13 Control module Replacethe heating/air-conditioningcontrol Control module faulty Fault code 32 Test point 14 Sunsensor Diagnosis conditions No control module fault stored. Short to B+ No fault with supplyvoltage (5 volts). Short to ground Fault code 33 Short to B+/ Short to ground 1. Removesun sensor. 2. Removeplug connectionfrom sunsensor. 8 80 -D 30 80 01 Diagnosis/troubleshooting, heating 99680Dl Printed in Germany -11, 1998.