996 Carrera Group 0 Part 2 Diagnosis / PAGE 161
Heating diagnosis 911 Carrera (996) · Fault, Fault code Possible causes, elimination, notes
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
Heating diagnosis 911 Carrera (996)
Fault, Fault code Possible causes, elimination, notes
Voltage too high
Note
A higher blower voltage can only be caused by a short to ground
on the wires to pins 1 or 2 of the driver.
1. UnplugconnectorC from the heating/air-conditioningcontrol.
2. Unplug connector from the driver,
3. Connectohmmeter to C 16 and ground.
Display: 00 .Q
4. Unplug connector from the fan motor.
5. Connectohmmeter to driver connector pin 2 and ground.
Display: 00 .0.
Test point 13
Control module Replacethe heating/air-conditioningcontrol
Control module faulty
Fault code 32
Test point 14
Sunsensor Diagnosis conditions
No control module fault stored.
Short to B+ No fault with supplyvoltage (5 volts).
Short to ground
Fault code 33 Short to B+/ Short to ground
1. Removesun sensor.
2. Removeplug connectionfrom sunsensor.
8
80 -D 30 80 01 Diagnosis/troubleshooting, heating
99680Dl Printed in Germany -11, 1998.
This is a source reference. Confirm exact model applicability in the original material.