996 Carrera Group 0 Part 2 Diagnosis / PAGE 198
Test point 5 · Door lock barrel open Troubleshootingin accordancewith test point 3
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
Test point 5
Door lock barrel open Troubleshootingin accordancewith test point 3
Short to ground
Fault code 05
Test point 6
Door lock barrel 1. Pull off plug I on the alarm control module.
open/closed 2. Disconnectplug connection X 11 (driver's side).
Short to ground
Fault code 06 3. Disconnectthe plug connection X 12 (passenger'sside).
4. Check the leads from the alarm control module plug I pin 35
to the door lock modulesfor short to ground.
Ohmmeter at alarm control module plug I pin 35 and ground
Display: 00.Q
5. Check driver's side door lock module switch contact.
Ohmmeter at plug connection X 11 pin A4 (sleeve side) and ground.
Door lock not actuated.
Display: 00Q
Door lock actuated towards "Closed",
Display: < 5 Q
6. Check passenger'sside door lock module switch contact.
Ohmmeter at plug connection X 12 pin A4 (sleeve side) and ground.
Door lock not actuated.
Display: 00Q
Door lock actuated towards "Closed"
Display: < 5 .Q
7. Check the leads from the alarm control module plug I pin 15
to the door lock modules for short to ground.
9001 90 -D 31
This is a source reference. Confirm exact model applicability in the original material.