996 Carrera Group 0 Part 2 Diagnosis / PAGE 198

Test point 5 · Door lock barrel open Troubleshootingin accordancewith test point 3

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 198
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

Test point 5 Door lock barrel open Troubleshootingin accordancewith test point 3 Short to ground Fault code 05 Test point 6 Door lock barrel 1. Pull off plug I on the alarm control module. open/closed 2. Disconnectplug connection X 11 (driver's side). Short to ground Fault code 06 3. Disconnectthe plug connection X 12 (passenger'sside). 4. Check the leads from the alarm control module plug I pin 35 to the door lock modulesfor short to ground. Ohmmeter at alarm control module plug I pin 35 and ground Display: 00.Q 5. Check driver's side door lock module switch contact. Ohmmeter at plug connection X 11 pin A4 (sleeve side) and ground. Door lock not actuated. Display: 00Q Door lock actuated towards "Closed", Display: < 5 Q 6. Check passenger'sside door lock module switch contact. Ohmmeter at plug connection X 12 pin A4 (sleeve side) and ground. Door lock not actuated. Display: 00Q Door lock actuated towards "Closed" Display: < 5 .Q 7. Check the leads from the alarm control module plug I pin 15 to the door lock modules for short to ground. 9001 90 -D 31