996 Carrera Group 0 Part 2 Diagnosis / PAGE 239
Alarm system diagnosis 911 Carrera (996) · 10. Press the double arrow key [»] to set up 17, The following
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
Alarm system diagnosis 911 Carrera (996)
10. Press the double arrow key [»] to set up 17, The following message appears on the
communication with the new control module. screen:
"Pleaseconfirm input",
11. Select menu item Learning functionswith the Check the input key learning code and press
arrow key [v] and press the double arrow the key [F7].
key [»].
18. The following message appears on the
12. The menu item Immobilizer is already screen:
selected. Press the double arrow key [»]. "Remotecontrols were transferred"
Caution! 19. Select menu item Transponderkey with the
The immobilizer code can be arrow key [1\] and press the double arrow
input only once. An incorrect key [»].
input will render the control& module useless. 20. The following mess-ageappears on the
> Input and check immobilizer code screen:
"Input key learning code". carefully
Input the key learning code with the arrow
13. The following message appears on the keys [v] or [,,] and press the double arrow
screen: key [»].
"Input immobilizer code".
Input the immobilizer code with the arrow 21. The following message appears on the
keys [v] or [A] and press the double arrow screen:
key [»]. "Pleaseconfirm input".
Check the input key learning code and press
14. The following message appears on the the key [F7].
screen:
"Pleaseconfirm input".
Check the input immobilizer code and press
the key [F7].
15. Select menu item Remote control transfer
with the arrow key [v] and press the double
arrow key [»].
16. The following message appears on the
screen:
"Input key learning code".
Input the key learning code with the arrow
keys [v] or [tJ and press the double arrow
key [»].
This is a source reference. Confirm exact model applicability in the original material.