911 Carrera (996) HBA diagnosis
Calibration
The control module can be calibrated under menu item Calibration.Calibrationis necessary in the
following cases:
When replacing the servomotors for HBA
When replacing the entire headlights
When replacing the control module
Whenreplacinganglesensorsfor HBA
When modifying the running gear
Note:
Adjust the headlights after calibration.
Procedure:
1. Connect PST2 and switch on the ignition
2. Select vehicle type 911 (996) and start the
automatic control module search.
3. SelectcontrolmoduleHBA.
4. Select menu item Calibration and follow the
instructions displayed by the PST2
Note:
The servomotors will be activated in the three
possible positions -max. position, centre
position and min. position -during calibration.
Observethis process with the dipped beam
switched on. Read out the fault memory after
calibration.
94 92 Diagnosis/troubleshooting HBA 94 -D 27