Calibration · The control module can be calibrated under menu item Calibration.Calibrationis necessary in the

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 383
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

911 Carrera (996) HBA diagnosis Calibration The control module can be calibrated under menu item Calibration.Calibrationis necessary in the following cases: When replacing the servomotors for HBA When replacing the entire headlights When replacing the control module Whenreplacinganglesensorsfor HBA When modifying the running gear Note: Adjust the headlights after calibration. Procedure: 1. Connect PST2 and switch on the ignition 2. Select vehicle type 911 (996) and start the automatic control module search. 3. SelectcontrolmoduleHBA. 4. Select menu item Calibration and follow the instructions displayed by the PST2 Note: The servomotors will be activated in the three possible positions -max. position, centre position and min. position -during calibration. Observethis process with the dipped beam switched on. Read out the fault memory after calibration. 94 92 Diagnosis/troubleshooting HBA 94 -D 27