Group 0 · General / PAGE 245

Input and output signals of control units (simplified diagram) · ? CAN low DME ? ? Solenoid

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 245
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

911 Transmission 3 Input and output signals of control units (simplified diagram) ? CAN low DME ? ? Solenoid valve 1 - 2/4 - 5 ? CAN high DME ? ? Solenoid valve 2 - 3 Speed sensor ? ? Solenoid valve 3 -4 TIPTRONIC Speed sensor ? CONTROL ? PWM valve, torque converter lockup UNIT clutch Terminal 30 ? ? Control solenoid for modulating pres- Terminal 15 ? sure Terminal 31 ? ? Control solenoid for shifting pressure ? CAN low PSM ? ? Voltage supply for solenoid valves ? CAN high PSM ? ? Voltage supply for sensors ? CAN low instr. ? ? Earth for sensors ? CAN high instr. ? Diagnosis ? ? Shift-lock solenoid Oil temperature ? 2002 Service Information 3 -19