Group 2 · Engine electronics / PAGE 72Open full manual
27 22 19 Removing and installing three-phase generator -GT3 · 1. Disconnectthe battery and cover terminal or
Add to repair workspace
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
911 Carrera (996) Starter, power supply, cruise control
27 22 19 Removing and installing three-phase generator -GT3
Removal
1. Disconnectthe battery and cover terminal or / ~
battery. Undo the fastening screw for the air
//'" cleaner housing and the hose clamp on the
air flow sensor.
#
2. Disconnect the electrical plug connection on --- the air flow sensor and remove the complete
air cleaner assembly.
I' j \
~r
.:...~-=-~~
057_99
7. Undo right fastening screw by three turns. A
gentle tap on the fastening screw loosensthe
threaded bushing in the three-phasegenerator
arm (use aluminiummandrel). Unscrew
fastening screw.
8. Removethree-phasegenerator and carefully
pull a little to the rear. Press the plug
058_99 connection towards the three-phasegenerator
housing,release and pull off. Pull out
3. Relievethe drive belt on the tensioning pulley three-phasegenerator to the rear.
and remove the belt.
9. Undo B+ lead on the three-phasegenerator.
4. Removethe deflection roller under the
three-phasegenerator.
5. Disconnectthe cable lug of the B+ lead
to the three-phasegenerator at
the B+ disconnectionpoint.
6. Undo left fastening screw (in direction
of travel) and unscrew.
27 22 19 Removing and installing three-phase generator -GT3 27 -9
Printed in Germany -25, 1999 GT3277
~