Group 2 · Engine electronics / PAGE 84Open full manual
Starter, power supply, cruise control 911 Carrera (996) · 24 70 DME control module: Remedy:
Add to repair workspace
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
Starter, power supply, cruise control 911 Carrera (996)
24 70 DME control module: Remedy:
Perform a test drive. During the test drive, drive
After disconnection of the power supply, the idle the vehicle with varying load conditionsand
speed might change or fluctuate briefly until the speeds so that all shift functions (manualand
idle speed positioner (M 5.2) or the throttle automatic programs) are executed at least
adjusting unit (ME 7.2) is readapted. The mixture once. This readapts the shifting pressures of
adaptation is also lost. the system and thereby re-establishessmooth
shifting.Remedy:
After the b~tteryis connected: 64 52 Power windows:
With the DME ME 7.2, it is necessaryto carry The limit positions of the power windows are
out a learning and adaptation routine as deleted from the control module when the
described below: battery is disconnectedand connected.
Switch the ignition on for 1 minute without Remedy:
starting the engine. Do not actuate
Manuallyclose each power window as far as it accelerator pedal.
will go, then press the rocker switch for closing
the window again. Switchoff ignitionfor at least 10 seconds.
The limit position of the respective power
window is now stored in the control moduleThiscompletesthe adaptationof the throttle
adjustingunit. again.
With all DME systems, the engine must run 90 25 Instrument cluster:
for several minutes before the engine
control module can relearn the idle speed The trip counter is set to 0 when the power
and mixture adaptation values. supply is disconnected.
37 30 Tiptronic: 90 30 Clock:
The stored pressure adaptation valves are Dependingon the software version, the clock is
lost if the power supply to terminal 30 is set to 12:00 a.m. or 1:00 a.m. when the power
interrupted. This can result in poor shifting supply is disconnected.
quality (rough shift operations)during the
adaptation phase. Remedy:
Enter the current time again.
Note:
Onvehicleswith PCM,91 10 PCMposition3.
27 -22 27 06 Work instructions after disconnecting the battery
9962721 Printed in Germany -33, 1999
This is a source reference. Confirm exact model applicability in the original material.