Group 9 · Electrics / PAGE 21
8703 Safety regulations when handling refrigerant R 134a · The refrigerant R 134a which is used is known 4. Refr
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
8703 Safety regulations when handling refrigerant R 134a
The refrigerant R 134a which is used is known 4. Refrigerantbottles must not be thrown and
as a safety refrigerant. This means'that this re- must not be subjected to direct sunlightor
frigerant is non-flammable,non-explosive,non- other heat sources for an extended period
toxic, non-irritating, odorless and tasteless. De- when full. The maximum permissible
spite this, you should still follow the points below. temperature of a filled refrigerant bottle
must not exceed 45 aG.
1. Avoid all contact with liquid or gaseous refri-
gerants. Treat affected skin in the same way
as in the case of freezing. Rinse immediately
and then consult a physician.Wear safety
goggles to protect your eyes. If refrigerant
still gets in your eyes, consult a physician
immediately. Wear rubber gloves to protect
your hands.
2. When carrying out repairs on the air-condi-
tioning system, the system must be emptied
by suction and the refrigerant must be puri-
fied. Chlorine-freerefrigerants must also not
be allowed to escape into the atmosphere and
must be disposed of correctly.
Due to their chemical composition, different
refrigerants must not be mixed with each
other (not even in small quantities).
3. Never perform welding work on parts of the
closed air-conditioningsystem or in its immedi-
ate vicinity. Whether or not the system is filled
with refrigerant, the heating causes a very
strong overpressurewhich can cause damage
to the system or even lead to an explosion.
R 134a is completely non-toxic at normal
temperatures, but it decomposesupon con-
tact with a flame or at high temperatures.
87 03 Safety regulations when handling refrigerant R 134a 87-1
Printed in Germany, 1997 996871