Running-in regulations for new compressor
Note
Fill the air-conditioningsystem (fluid)via the high-
pressure side from the refrigerant circuit with
the engine "OFF".
1. If possible, all air outlet nozzles "OPEN",
circulating air "CLOSED",
2. Start the engineand allowidle speedto
stabilize(approx.5 seconds).
3. Set the fan to max. output.
4. Switch on the air-conditioningsystem (AC
switch) and allow it to run uninterruptedfor
at least 2 minutes at 1500 rpm.
5. After 2 minutes uninterrupted compressor
operation time, the oil distribution in the air-
conditioning system is completed and the
compressor can be run up to the max. engine
speed.
87 34 19 Removing and installing the compressor 87 -21