Running-in regulations for new compressor Note Fill the air-conditioningsystem (fluid)via the high- pressure side from the refrigerant circuit with the engine "OFF". 1. If possible, all air outlet nozzles "OPEN", circulating air "CLOSED", 2. Start the engineand allowidle speedto stabilize(approx.5 seconds). 3. Set the fan to max. output. 4. Switch on the air-conditioningsystem (AC switch) and allow it to run uninterruptedfor at least 2 minutes at 1500 rpm. 5. After 2 minutes uninterrupted compressor operation time, the oil distribution in the air- conditioning system is completed and the compressor can be run up to the max. engine speed. 87 34 19 Removing and installing the compressor 87 -21 Printed in Germany, 1997 996871