996 Turbo diagnostic manual — Turbo applicability only / PAGE 63
PSM 05 911 Turbo (996)45 · pump motor and checking their feedback. It only makes sense to
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
PSM 05 911 Turbo (996)45
pump motor and checking their feedback. It only makes sense to
carry out the "Static test" function if no fault has previously been
detected as present, i.e. the system has not switched off.
Note!
This test must be carried out after the hydraulic unit has been
exchanged.
Swap test
The swap test is used to check the allocation of the brake pressure
lines to the wheel brake cylinders. A hydraulic and an electrical test
are carried out.
Note!
This test must be carried out after the hydraulic unit has been
exchanged.
Bleeding
The brake system can be bled using this menu item.
⇒Rep. Gr. 470107; Bleeding brakes
Steering-angle sensor calibration
The steering-angle sensor can be calibrated with this menu item.
The steering-angle sensor must be calibrated after work has been
carried out on the running gear in the area of the front axle. The
security code is required for calibration of the steering-angle sen-
sor. The security code is contained under menu item "Actual
values".⇒Rep. Gr. 4560; Steering-angle sensor calibration
45-5 page 4 4503 Control module function
SGF_ps05 Printed in Germany – 5, 2001
This is a source reference. Confirm exact model applicability in the original material.