996 Turbo diagnostic manual — Turbo applicability only / PAGE 113

45-33Fault code 4802 · Undervoltage

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 113
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

911 Turbo (996) PSM 05 45 45-33Fault code 4802 Undervoltage Diagnostic conditions • Internal control module function test • Voltage less than 9.8 V (voltage supply for control module, rate- of-turn sensor and steering angle sensor) • Vehicle speed is greater than 6 km/h Note! Once the vehicle voltage is within the permissible voltage range again, the PSM system is switched back on and the indicator lights go out. Possible cause of fault ♦Vehicle voltage was too low ♦Faulty connection to PSM control module Affected terminals Terminals 1, 5 and 23 Diagnosis/troubleshooting Work instruction Display OK If not OK 1 Check ground for open ♦Switch off ignition < 5 Ω Open circuit or high circuit ⇒ Step 2 contact resistance ♦Pull off the PSM control module between pins 1 and plug 5 of PSM control ♦Measure resistance between module plug and PSM control module plug pins 1 PSM ground point and 5 and ground → End 2 Erase fault memory and read out again after test drive → End 4503 Fault code 4802 45-33 page 1 Printed in Germany – 4, 2001 4802ps05

This is a source reference. Confirm exact model applicability in the original material.