996 Turbo diagnostic manual — Turbo applicability only / PAGE 113
45-33Fault code 4802 · Undervoltage
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
911 Turbo (996) PSM 05 45
45-33Fault code 4802
Undervoltage
Diagnostic conditions
• Internal control module function test
• Voltage less than 9.8 V (voltage supply for control module, rate-
of-turn sensor and steering angle sensor)
• Vehicle speed is greater than 6 km/h
Note!
Once the vehicle voltage is within the permissible voltage range
again, the PSM system is switched back on and the indicator lights
go out.
Possible cause of fault
♦Vehicle voltage was too low
♦Faulty connection to PSM control module
Affected terminals
Terminals 1, 5 and 23
Diagnosis/troubleshooting
Work instruction Display OK If not OK
1 Check ground for open ♦Switch off ignition < 5 Ω Open circuit or high
circuit ⇒ Step 2 contact resistance ♦Pull off the PSM control module
between pins 1 and plug
5 of PSM control
♦Measure resistance between module plug and
PSM control module plug pins 1 PSM ground point
and 5 and ground → End
2 Erase fault memory and read out again after test drive → End
4503 Fault code 4802 45-33 page 1
Printed in Germany – 4, 2001 4802ps05