996 Turbo diagnostic manual — Turbo applicability only / PAGE 318
72-6Fault overview · Fault code Fault text Fault effect
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
911 Turbo (996) Seat memory S02; S03; 72
72-6Fault overview
Fault code Fault text Fault effect
1 Control module faulty (main relay does not drop No adjustment
out)
2 Control module faulty (main relay does not pick No adjustment
up)
3 Control module faulty (A/D converter faulty) No adjustment
4 EEPROM fault (checksum) Default values
5 EEPROM fault, Required position 1 (checksum) No automatic adjustment possible
6 EEPROM fault, Required position 2 (checksum) No automatic adjustment possible
7 EEPROM fault, Required position 3 (checksum) No automatic adjustment possible
8 Hall-effect sensor for fore-and-aft adjustment - No automatic adjustment possible, manual only
open circuit 500 ms
9 Hall-effect sensor for fore-and-aft adjustment - No automatic adjustment possible, manual only
short circuit 500 ms
10 Hall-effect sensor for backrest adjustment - No automatic adjustment possible, manual only
open circuit 500 ms
11 Hall-effect sensor for backrest adjustment - No automatic adjustment possible, manual only
short circuit 500 ms
12 Hall-effect sensor for front height adjustment - No automatic adjustment possible, manual only
open circuit 500 ms
13 Hall-effect sensor for front height adjustment - No automatic adjustment possible, manual only
short circuit 500 ms
14 Hall-effect sensor for rear height adjustment - No automatic adjustment possible, manual only
open circuit 500 ms
15 Hall-effect sensor for rear height adjustment - No automatic adjustment possible, manual only
short circuit 500 ms
18 Lumbar pressure sensor - open circuit No automatic lumbar adjustment possible
19 Lumbar pressure sensor - short circuit No automatic lumbar adjustment possible
20 Pot. mirror right horizontal - open circuit No automatic adjustment possible
21 Pot. mirror right horizontal - short circuit No automatic adjustment possible
22 Pot. mirror right vertical - open circuit No automatic adjustment possible
23 Pot. mirror right vertical - short circuit No automatic adjustment possible
24 Pot. mirror left horizontal - open circuit No automatic adjustment possible
25 Pot. mirror left horizontal - short circuit No automatic adjustment possible
26 Pot. mirror left vertical - open circuit No automatic adjustment possible
27 Pot. mirror left vertical - short circuit No automatic adjustment possible
32 Button M, 1, 2, 3 or operating buttons actuated Switch is ignored; all further adjustments are
for longer than 60 seconds jerky
7298 Fault overview 72-6 page 1
Printed in Germany – 42, 2003 Fue_XS02
This is a source reference. Confirm exact model applicability in the original material.