996 Turbo diagnostic manual — Turbo applicability only / PAGE 320
72-7Fault code 1 · Control module faulty (main relay does not drop out)
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
911 Turbo (996) Seat memory S02 72
72-7Fault code 1
Control module faulty (main relay does not drop out)
Diagnostic conditions
• Ignition on
• Switch for memory seat adjustment actuated
Possible cause of fault
♦Temporary system error
♦Control module faulty
Affected terminals
-
Diagnosis/troubleshooting
Work instruction Display OK If not OK
1 Erase fault memory ⇒ Step 2
2 Read out fault memory Fault code 1 is no Fault code 1 is still
longer present present
⇒ Step 3 ⇒ Step 4
3 Check function of system components → End ⇒ Step 4
4 Replace control module → End
7298 Fault code 1 72-7 page 1
Printed in Germany – 3, 2001 1xxxxS02