996 Turbo diagnostic manual — Turbo applicability only / PAGE 322
72-9Fault code 3 · A/D converter faulty
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
911 Turbo (996) Seat memory S02 72
72-9Fault code 3
A/D converter faulty
Diagnostic conditions
• Ignition on
• Switch for memory seat adjustment actuated
Possible cause of fault
♦Control module faulty
Affected terminals
-
Diagnosis/troubleshooting
Work instruction Display OK If not OK
1 Erase fault memory ⇒ Step 2
2 Read out fault memory Fault code 3 is no Fault code 3 is still
longer present⇒ present ⇒ Step 4
Step 3
3 Check function of system components → End
4 Replace control module → End
7298 Fault code 3 72-9 page 1
Printed in Germany – 3, 2001 3xxxxS02
This is a source reference. Confirm exact model applicability in the original material.