996 Turbo diagnostic manual — Turbo applicability only / PAGE 322

72-9Fault code 3 · A/D converter faulty

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 322
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

911 Turbo (996) Seat memory S02 72 72-9Fault code 3 A/D converter faulty Diagnostic conditions • Ignition on • Switch for memory seat adjustment actuated Possible cause of fault ♦Control module faulty Affected terminals - Diagnosis/troubleshooting Work instruction Display OK If not OK 1 Erase fault memory ⇒ Step 2 2 Read out fault memory Fault code 3 is no Fault code 3 is still longer present⇒ present ⇒ Step 4 Step 3 3 Check function of system components → End 4 Replace control module → End 7298 Fault code 3 72-9 page 1 Printed in Germany – 3, 2001 3xxxxS02