996 Turbo diagnostic manual — Turbo applicability only / PAGE 328
72-14Fault code 8 · Hall-effect sensor for fore-and-aft adjustment - open
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
911 Turbo (996) Seat memory S02 72
72-14Fault code 8
Hall-effect sensor for fore-and-aft adjustment - open
circuit
Diagnostic conditions
• Ignition on
• Switch for memory seat adjustment actuated
Possible cause of fault
♦Open circuit in supply lead to hall-effect sensor for fore-and-aft
adjustment
♦Hall-effect sensor faulty
♦Control module faulty
Affected terminals
Plug 4, terminals 2 and 3
Diagnosis/troubleshooting
Work instruction Display OK If not OK
1 Visual inspection ♦Check plug 4 for contact and ⇒ Step 2 Repair plug or wir-
damage ing harness
→ End
2 Check supply lead of the ♦Check supply lead to the sensor ⇒ Step 3 Repair wiring har-
sensor for damage ness
→ End
3 ♦Replace electric motor → End
for seat adjustment
7298 Fault code 8 72-14 page 1