911 Turbo (996) Seat memory S02 72 72-14Fault code 8 Hall-effect sensor for fore-and-aft adjustment - open circuit Diagnostic conditions • Ignition on • Switch for memory seat adjustment actuated Possible cause of fault ♦Open circuit in supply lead to hall-effect sensor for fore-and-aft adjustment ♦Hall-effect sensor faulty ♦Control module faulty Affected terminals Plug 4, terminals 2 and 3 Diagnosis/troubleshooting Work instruction Display OK If not OK 1 Visual inspection ♦Check plug 4 for contact and ⇒ Step 2 Repair plug or wir- damage ing harness → End 2 Check supply lead of the ♦Check supply lead to the sensor ⇒ Step 3 Repair wiring har- sensor for damage ness → End 3 ♦Replace electric motor → End for seat adjustment 7298 Fault code 8 72-14 page 1 Printed in Germany – 3, 2001 8xxxxS02