996 Turbo diagnostic manual — Turbo applicability only / PAGE 330

72-15Fault code 9 · Hall-effect sensor for fore-and-aft adjustment - short

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 330
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

911 Turbo (996) Seat memory S02; S03; 72 72-15Fault code 9 Hall-effect sensor for fore-and-aft adjustment - short circuit Diagnostic conditions • Ignition on • Switch for memory seat adjustment actuated Possible cause of fault ♦Short circuit in supply lead to hall-effect sensor ♦Hall-effect sensor faulty ♦Control module faulty Affected terminals Plug 4, terminals 2 and 3 Diagnosis/troubleshooting Work instruction Display OK If not OK 1 Check plug and sensor ♦Pull plug for fore-and-aft adjust- Step 2 Repair plug or wir- supply lead ment off the control module. ing harness. → End ♦Check plug for corrosion. ♦Check supply lead for signs of damage. 2 ♦Replace electric motor for seat adjustment → End Step 3 3 ♦Replace control module → End 7298 Fault code 9 72-15 page 1 Printed in Germany – 42, 2003 9xxxxS02