996 Turbo diagnostic manual — Turbo applicability only / PAGE 330
72-15Fault code 9 · Hall-effect sensor for fore-and-aft adjustment - short
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
911 Turbo (996) Seat memory S02; S03; 72
72-15Fault code 9
Hall-effect sensor for fore-and-aft adjustment - short
circuit
Diagnostic conditions
• Ignition on
• Switch for memory seat adjustment actuated
Possible cause of fault
♦Short circuit in supply lead to hall-effect sensor
♦Hall-effect sensor faulty
♦Control module faulty
Affected terminals
Plug 4, terminals 2 and 3
Diagnosis/troubleshooting
Work instruction Display OK If not OK
1 Check plug and sensor ♦Pull plug for fore-and-aft adjust- Step 2 Repair plug or wir-
supply lead ment off the control module. ing harness.
→ End ♦Check plug for corrosion.
♦Check supply lead for signs of
damage.
2 ♦Replace electric motor for seat adjustment → End Step 3
3 ♦Replace control module → End
7298 Fault code 9 72-15 page 1
Printed in Germany – 42, 2003 9xxxxS02
This is a source reference. Confirm exact model applicability in the original material.