996 Turbo diagnostic manual — Turbo applicability only / PAGE 332
72-16Fault code 10 · Hall-effect sensor for backrest adjustment - open cir-
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
911 Turbo (996) Seat memory S02 72
72-16Fault code 10
Hall-effect sensor for backrest adjustment - open cir-
cuit
Diagnostic conditions
• Ignition on
• Switch for memory seat adjustment actuated
Possible cause of fault
♦Open circuit in supply lead to hall-effect sensor for backrest
adjustment
♦Hall-effect sensor faulty
♦Control module faulty
Affected terminals
Plug 1, terminals 2 and 3
Diagnosis/troubleshooting
Work instruction Display OK If not OK
1 Check control module ♦Check control module plug for ⇒ Step 2 Repair plug
plug contact and damage → End
2 Check supply lead of the ♦Check supply lead to the sensor ⇒ Step 3 Repair wiring har-
sensor for damage ness
→ End
3 ♦Replace electric motor for backrest adjustment → End
7298 Fault code 10 72-16 page 1
Printed in Germany – 3, 2001 10xxxS02
This is a source reference. Confirm exact model applicability in the original material.