996 Turbo diagnostic manual — Turbo applicability only / PAGE 340
72-23Fault code 19 · Lumbar pressure sensor - short circuit
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
911 Turbo (996) Seat memory S02; S03; 72
72-23Fault code 19
Lumbar pressure sensor - short circuit
Diagnostic conditions
• Ignition on
• Switch for memory seat adjustment actuated
Possible cause of fault
♦Short circuit to voltage/ground or open circuit in pressure sen-
sor supply lead
♦Pressure sensor faulty
♦Control module faulty
Affected terminals
Plug 9, pins 1, 2 and 3
Diagnosis/troubleshooting
Work instruction Display OK If not OK
1 Visual inspection ♦Check plug 9 on control mod- Step 2 Connect plug 9 or
ule for corrosion and contact. repair wiring har-
ness. ♦Check supply lead on plug 9
→ End for damage.
2 Check power supply of ♦Switch off ignition. Approx. 5 V Step 5
the sensor Step 3 ♦Pull off plug on lumbar adjust-
ment device (pressure sensor).
♦Measure voltage between pin 1
and ground.
3 Check ground lead of the ♦Measure voltage on plug of Approx. 5 V Step 8
sensor lumbar adjustment device Step 4
(pressure sensor), between
pins 1 and 3.
4 Check signal lead of the ♦Select 'Pressure sensor volt- 0 V without jumper Step 9
sensor age' in the Actual values menu Approx. 5 V with
item. jumper
Step 12 ♦Connect jumper between pins
1 and 2.
7298 Fault code 19 72-23 page 1
Printed in Germany – 42, 2003 19xxxs02