fullymatted.
Back to search
996 Turbo diagnostic manual — Turbo applicability only / PAGE 364

80-4Connector assignment · Connector assignment for air-conditioning control

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 364
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

911 Turbo (996) Air conditioning H01, H02 80 80-4Connector assignment Connector assignment for air-conditioning control module The two plugs, A and C, are replaced by networking (used by CAN- Comfort Bus). The signals required for function or control are exchanged via the CAN Bus lines CAN Comfort high and CAN Com- fort low. Connector B (red) Pin Designation Pin Designation 1 CAN Comfort high 11 Cooler checkback signal + 2 CAN Comfort low 12 Cooler activation 3 Footwell/defrost flap checkback signal 13 Temperature mixing valve checkback signal 4 Not used 14 Central flap checkback signal 5 Outside temperature sensor (air intake) 15 Not used 6 Interior temperature sensor 16 Compresser voltage 7 Temperature sensor (blower outlet sen- 17 Outside air / recirculation valve checkback sor,footwell) signal 8 Not used 18 Not used 9 Ground sensor 19 Information system 10 Temperature mixing valve motor 20 +5 V 8001 Connector assignment 80-4 page 1 Printed in Germany – 15, 2001 stb_xh02

This is a source reference. Confirm exact model applicability in the original material.