996 Turbo diagnostic manual — Turbo applicability only / PAGE 364
80-4Connector assignment · Connector assignment for air-conditioning control
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
911 Turbo (996) Air conditioning H01, H02 80
80-4Connector assignment
Connector assignment for air-conditioning control
module
The two plugs, A and C, are replaced by networking (used by CAN-
Comfort Bus). The signals required for function or control are
exchanged via the CAN Bus lines CAN Comfort high and CAN Com-
fort low.
Connector B (red)
Pin Designation Pin Designation
1 CAN Comfort high 11 Cooler checkback signal +
2 CAN Comfort low 12 Cooler activation
3 Footwell/defrost flap checkback signal 13 Temperature mixing valve checkback signal
4 Not used 14 Central flap checkback signal
5 Outside temperature sensor (air intake) 15 Not used
6 Interior temperature sensor 16 Compresser voltage
7 Temperature sensor (blower outlet sen- 17 Outside air / recirculation valve checkback
sor,footwell) signal
8 Not used 18 Not used
9 Ground sensor 19 Information system
10 Temperature mixing valve motor 20 +5 V
8001 Connector assignment 80-4 page 1
Printed in Germany – 15, 2001 stb_xh02