996 Turbo diagnostic manual — Turbo applicability only / PAGE 391
80-16Fault code 30 · AC - signal unclear
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
911 Turbo (996) Air conditioning H01, H02 80
80-16Fault code 30
AC - signal unclear
Diagnostic conditions
• This fault can be determined only during the system test.
Possible cause of fault
♦Fuse D6 faulty
♦Refrigerant pressure too low or non-existent
♦Line fault between pressure switch, relay for fresh-air blower,
relay for magnetic clutch, DME control module or air-condition-
ing compressor
♦Pressure switch faulty
♦Relay for fresh-air blower faulty
♦Relay for magnetic clutch faulty
Affected terminals
Plug B, terminal 16
Diagnosis/troubleshooting
Work instruction Display OK If not OK
1 Check fuse D6 ♦Check fuse D6 ⇒ Step 2 Replace fuse D6
2 Check refrigerant pressure ⇒ Step 3 Fill system
Carry out system
testing
→ End
2 Check line between relay ♦Switch off ignition Battery voltage ⇒ Step 10
for fresh-air blower and ⇒ Step 3 ♦Remove plug from pressure
pressure switch switch.
♦Measure voltage at plug of the
pressure switch between pin 4
and ground
♦Switch on ignition
3 Check pressure switch ♦Measure resistance at the pres- < 5Ω Replace pressure
sure switch between pins 1 and ⇒ Step 4 switch
4 Carry out system
testing
→ End
8001 Fault code 30 80-16 page 1
Printed in Germany – 15, 2001 30xxxh02