fullymatted.
Back to search
996 Turbo diagnostic manual — Turbo applicability only / PAGE 391

80-16Fault code 30 · AC - signal unclear

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 391
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

911 Turbo (996) Air conditioning H01, H02 80 80-16Fault code 30 AC - signal unclear Diagnostic conditions • This fault can be determined only during the system test. Possible cause of fault ♦Fuse D6 faulty ♦Refrigerant pressure too low or non-existent ♦Line fault between pressure switch, relay for fresh-air blower, relay for magnetic clutch, DME control module or air-condition- ing compressor ♦Pressure switch faulty ♦Relay for fresh-air blower faulty ♦Relay for magnetic clutch faulty Affected terminals Plug B, terminal 16 Diagnosis/troubleshooting Work instruction Display OK If not OK 1 Check fuse D6 ♦Check fuse D6 ⇒ Step 2 Replace fuse D6 2 Check refrigerant pressure ⇒ Step 3 Fill system Carry out system testing → End 2 Check line between relay ♦Switch off ignition Battery voltage ⇒ Step 10 for fresh-air blower and ⇒ Step 3 ♦Remove plug from pressure pressure switch switch. ♦Measure voltage at plug of the pressure switch between pin 4 and ground ♦Switch on ignition 3 Check pressure switch ♦Measure resistance at the pres- < 5Ω Replace pressure sure switch between pins 1 and ⇒ Step 4 switch 4 Carry out system testing → End 8001 Fault code 30 80-16 page 1 Printed in Germany – 15, 2001 30xxxh02

This is a source reference. Confirm exact model applicability in the original material.