996 Turbo diagnostic manual — Turbo applicability only / PAGE 394
Air conditioning H01, H02 911 Turbo (996)80 · Work instruction Dis
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
Air conditioning H01, H02 911 Turbo (996)80
Work instruction Display OK If not OK
3 Check relay for fresh-air ♦Switch off ignition Battery voltage Relay for heating
blower ⇒ Step 4 activation faulty or ♦Remove plug B from the air-
short circuit to conditioning system regulator
ground or open cir-
♦Reconnect heating activation cuit in the line
once more between heating
♦Switch on ignition activation relay and
the air-conditioning ♦Measure voltage between plug
system regulator B 11 and ground
4 Check blower regulator ♦Switch off ignition Fault has been rem- ⇒ Step 6
(end setting) edied ♦Reconnect plug B to the air-
⇒Step 5 conditioning system regulator
♦Switch on ignition
♦Bridge terminals K2 and K3 on
blower regulator
♦Switch on blower
5 Check blower regulator ♦Switch off ignition < 5 Ω Repair wiring har-
(end setting) and line for ⇒Step 9 ness ♦Remove plug B from the air-
air-conditioning system → End conditioning system regulator
regulator
♦Remove plug from blower regu-
lator
♦Measure resistance between
plug B on the air-conditioning
system regulator pin 12 and
plug on blower regulator pin K
1
6 Check line to blower ♦Switch off ignition 0 V Repair wiring har-
motor for short to B+ ⇒ Step 5 ness ♦Remove plug from blower
→ End motor
♦Switch on ignition
♦Measure voltage between plug
on the blower motor pin L2 and
ground
♦Measure voltage between plug
on the blower motor pin L1 and
ground
7 Check line to blower ♦Measure resistance between ∞ Ω Repair wiring har-
motor for short to plug on the blower motor pin ⇒ Step 6 ness
ground L2 and ground → End
80-17 page 2 8001 Fault code 31
31xxxh02 Printed in Germany – 15, 2001
This is a source reference. Confirm exact model applicability in the original material.