996 Turbo diagnostic manual — Turbo applicability only / PAGE 398
Air conditioning H01, H02 911 Turbo (996)80 · Diagnosis/troubleshooting
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
Air conditioning H01, H02 911 Turbo (996)80
Diagnosis/troubleshooting
Work instruction Display OK If not OK
1 Check CAN bus leads, ♦Switch off ignition ∞ Ω Repair wiring har-
CAN-high and CAN-low for ⇒ Step 2 ness ♦Remove plug A from the instru-
short circuit. → End ment cluster
♦Remove plug of the air-condition-
ing system regulator
♦Measure resistance on plug A of
the instrument cluster between
pin 14 and pin 30
2 Check CAN bus lead, ♦Measure resistance between ∞ Ω Repair wiring har-
CAN-high for short to plug A on instrument cluster pin ⇒ Step 3 ness
ground 14 and ground → End
3 Check CAN bus lead, ♦Switch on ignition 0 V Repair wiring har-
CAN-low for short to B+ ⇒ Step 4 ness ♦Measure voltage between plug A
→ End on instrument cluster pin 30 and
ground
4 Determine faulty control ♦Switch off ignition Fault has been reme- The fault is still
unit died present ⇒ Step 6 ♦Reattach the plugs on instru-
⇒Step 5 ment cluster
♦ Read out fault memory from
instrument cluster and check
whether the fault "CAN Comfort
Bus" has been remedied.
5 ♦Replace air-conditioning system regulator → End
6 ♦Replace instrument cluster → End
80-19 page 2 8001 Fault code 34
34xxxh02 Printed in Germany – 15, 2001
This is a source reference. Confirm exact model applicability in the original material.