fullymatted.
Back to search
996 Turbo diagnostic manual — Turbo applicability only / PAGE 398

Air conditioning H01, H02 911 Turbo (996)80 · Diagnosis/troubleshooting

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 398
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

Air conditioning H01, H02 911 Turbo (996)80 Diagnosis/troubleshooting Work instruction Display OK If not OK 1 Check CAN bus leads, ♦Switch off ignition ∞ Ω Repair wiring har- CAN-high and CAN-low for ⇒ Step 2 ness ♦Remove plug A from the instru- short circuit. → End ment cluster ♦Remove plug of the air-condition- ing system regulator ♦Measure resistance on plug A of the instrument cluster between pin 14 and pin 30 2 Check CAN bus lead, ♦Measure resistance between ∞ Ω Repair wiring har- CAN-high for short to plug A on instrument cluster pin ⇒ Step 3 ness ground 14 and ground → End 3 Check CAN bus lead, ♦Switch on ignition 0 V Repair wiring har- CAN-low for short to B+ ⇒ Step 4 ness ♦Measure voltage between plug A → End on instrument cluster pin 30 and ground 4 Determine faulty control ♦Switch off ignition Fault has been reme- The fault is still unit died present ⇒ Step 6 ♦Reattach the plugs on instru- ⇒Step 5 ment cluster ♦ Read out fault memory from instrument cluster and check whether the fault "CAN Comfort Bus" has been remedied. 5 ♦Replace air-conditioning system regulator → End 6 ♦Replace instrument cluster → End 80-19 page 2 8001 Fault code 34 34xxxh02 Printed in Germany – 15, 2001