996 Turbo diagnostic manual — Turbo applicability only / PAGE 400

80-21Fault code 36 · CAN-timeout instrument cluster

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 400
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

911 Turbo (996) Air conditioning H01, H02 80 80-21Fault code 36 CAN-timeout instrument cluster Diagnostic conditions • Ignition on Possible cause of fault ♦Open circuit of CAN-high Comfort ♦Open circuit of CAN-low Comfort ♦Instrument cluster faulty Note! ♦The CAN Comfort is connected to the following control modules: ♦Air-conditioning control module ♦Instrument cluster Affected terminals Plug B, terminals 1 and 2 Diagnosis/troubleshooting Work instruction Display OK If not OK 1 Read out instrument clus- ♦Check whether the instrument The fault is remedied ⇒ Step 2 ter fault memory cluster is still functional. Check → End power supply and instrument cluster fuse ♦Read out instrument cluster fault memory and remedy any possi- ble stored faults 2 Check CAN Comfort high ♦Switch off ignition < 5Ω Repair wiring har- for open circuit ⇒ Step 3 ness ♦Remove plug A from the instru- → End ment cluster ♦Pull plug off the control module of the air-conditioning system ♦Measure resistance between plug A on the instrument cluster pin 14 and plug B on control module of air-conditioning sytem pin 1 8001 Fault code 36 80-21 page 1 Printed in Germany – 15, 2001 36xxxh02