996 Turbo diagnostic manual — Turbo applicability only / PAGE 428
Instrument cluster K20 911 Turbo (996)90 · Diagnosis/troubleshooting
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
Instrument cluster K20 911 Turbo (996)90
Diagnosis/troubleshooting
Work instruction Display OK If not OK
1 Read out Tiptronic fault ♦Read out Tiptronic fault mem- The fault is remedied ⇒ Step 2
memory ory and remedy any stored → End
faults
2 Check CAN-high drive for ♦Switch off ignition < 5Ω Repair wiring har-
open circuit ⇒ Step 3 ness ♦Pull plug A off the instrument
→ End cluster
♦Pull plug D and B off the DME
control module
♦Pull plug off the Tiptronic control
module
♦Measure resistance between
plug A on the instrument cluster
pin 15 and plug on DME control
module pin 36
♦Measure resistance between
plug B on DME control module
pin 4 and plug on Tiptronic con-
trol module pin H
3 Check CAN-low drive for ♦Measure resistance between < 5Ω Repair wiring har-
open circuit plug A on the instrument cluster ⇒ Step 4 ness.
pin 31 and plug D on DME con- → End
trol module pin 37
♦Measure resistance between
plug B on DME control module
pin 3 and plug on Tiptronic con-
trol module pin L
4 ♦Replace Tiptronic control module to test → End
90-12 page 2 9025 Fault code 9112
9112xk20 Printed in Germany – 8, 2001
This is a source reference. Confirm exact model applicability in the original material.