996 Turbo diagnostic manual — Turbo applicability only / PAGE 428

Instrument cluster K20 911 Turbo (996)90 · Diagnosis/troubleshooting

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 428
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

Instrument cluster K20 911 Turbo (996)90 Diagnosis/troubleshooting Work instruction Display OK If not OK 1 Read out Tiptronic fault ♦Read out Tiptronic fault mem- The fault is remedied ⇒ Step 2 memory ory and remedy any stored → End faults 2 Check CAN-high drive for ♦Switch off ignition < 5Ω Repair wiring har- open circuit ⇒ Step 3 ness ♦Pull plug A off the instrument → End cluster ♦Pull plug D and B off the DME control module ♦Pull plug off the Tiptronic control module ♦Measure resistance between plug A on the instrument cluster pin 15 and plug on DME control module pin 36 ♦Measure resistance between plug B on DME control module pin 4 and plug on Tiptronic con- trol module pin H 3 Check CAN-low drive for ♦Measure resistance between < 5Ω Repair wiring har- open circuit plug A on the instrument cluster ⇒ Step 4 ness. pin 31 and plug D on DME con- → End trol module pin 37 ♦Measure resistance between plug B on DME control module pin 3 and plug on Tiptronic con- trol module pin L 4 ♦Replace Tiptronic control module to test → End 90-12 page 2 9025 Fault code 9112 9112xk20 Printed in Germany – 8, 2001