996 Turbo diagnostic manual — Turbo applicability only / PAGE 434
Instrument cluster K20 911 Turbo (996)90 · Diagnosis/troubleshooting
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
Instrument cluster K20 911 Turbo (996)90
Diagnosis/troubleshooting
Work instruction Display OK If not OK
1 Perform a drive-link test ♦Select the menu item "pointer" in The oil pressure indi- ⇒ Step 7
the drive links menu item cator is controlled to
the top value and ♦Perform the drive-link test with
then onto value 0 the key F8 and observe the
⇒ Step 2 movement of the oil pressure
indicator
2 Check output voltage of ♦Disconnect wire to Pin G of the approx. 5 V ⇒ Step 3
the instrument cluster sensor for the oil pressure indi- ⇒ Step 6
cator
♦Switch on ignition
♦Measure voltage between pin G
and ground
3 Check wire between ♦Switch off ignition ∞ Ω Repair wiring har-
instrument cluster and ⇒ Step 4 ness ♦Pull plug B off the instrument
sensor for oil pressure → End cluster
indicator for short to
♦Measure resistance between ground
plug B on instrument cluster pin
5 and ground
4 Check wire between ♦Switch on ignition 0 V Repair wiring har-
instrument cluster and ⇒ Step 5 ness ♦Measure voltage between plug B
sensor for oil pressure → End on instrument cluster pin 5 and
indicator for short to B+ ground
5 Check wire between ♦Switch off ignition < 5Ω Repair wiring har-
instrument cluster and ⇒ Step 7 ness. ♦Measure resistance between
sensor for oil level indica- → End plug B on the instrument cluster
tor for open circuit pin 5 and plug on the sensor of
oil pressure indicator, pin G
6 ♦Replace oil pressure indicator → End
7 ♦Replace instrument cluster → End
90-15 page 2 9025 Fault code 9121