fullymatted.
Back to search
996 Turbo diagnostic manual — Turbo applicability only / PAGE 441

90-19Fault code 9130 · Supply voltage

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 441
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

911 Turbo (996) Instrument cluster K20 90 90-19Fault code 9130 Supply voltage Diagnostic conditions • Engine running Note! The fault memory status (present / not present) is always updated when the motor is running. Possible cause of fault ♦Battery voltage too low Affected terminals Plug B, terminals 2 and 18 Diagnosis/troubleshooting Work instruction Display OK If not OK 1 Check battery ♦Examine battery ⇒ Step 2 Charge or replace battery → End 2 Check input voltage termi- ♦Switch off ignition Battery voltage Corrosion in the nal 15 ⇒ Step 3 plug connection or ♦Pull plug A off the instrument contact resistance cluster in the supply lead. ♦Switch on ignition Check and repair ♦Measure voltage between plug A wiring harness on instrument cluster pin 3 and → End ground 3 Check input voltage termi- ♦Measure voltage between plug B Battery voltage Corrosion in the nal 30 on instrument cluster pin 2 and ⇒ Step 4 plug connection or ground contact resistance in the supply lead. ♦Measure voltage between plug B Check and repair on instrument cluster pin 18 and wiring harness. ground 4 Check ground points ♦Measure the resistance between < 5 Ω Check or repair wir- plug A pin 1 and ground → End ing harness → End ♦Measure the resistance between plug A pin 17 and ground 9025 Fault code 9130 90-19 page 1 Printed in Germany – 8, 2001 9130xk20

This is a source reference. Confirm exact model applicability in the original material.