996 Turbo diagnostic manual — Turbo applicability only / PAGE 441
90-19Fault code 9130 · Supply voltage
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
911 Turbo (996) Instrument cluster K20 90
90-19Fault code 9130
Supply voltage
Diagnostic conditions
• Engine running
Note!
The fault memory status (present / not present) is always updated
when the motor is running.
Possible cause of fault
♦Battery voltage too low
Affected terminals
Plug B, terminals 2 and 18
Diagnosis/troubleshooting
Work instruction Display OK If not OK
1 Check battery ♦Examine battery ⇒ Step 2 Charge or replace
battery
→ End
2 Check input voltage termi- ♦Switch off ignition Battery voltage Corrosion in the
nal 15 ⇒ Step 3 plug connection or ♦Pull plug A off the instrument
contact resistance cluster
in the supply lead.
♦Switch on ignition Check and repair
♦Measure voltage between plug A wiring harness
on instrument cluster pin 3 and → End
ground
3 Check input voltage termi- ♦Measure voltage between plug B Battery voltage Corrosion in the
nal 30 on instrument cluster pin 2 and ⇒ Step 4 plug connection or
ground contact resistance
in the supply lead. ♦Measure voltage between plug B
Check and repair on instrument cluster pin 18 and
wiring harness. ground
4 Check ground points ♦Measure the resistance between < 5 Ω Check or repair wir-
plug A pin 1 and ground → End ing harness
→ End ♦Measure the resistance between
plug A pin 17 and ground
9025 Fault code 9130 90-19 page 1
Printed in Germany – 8, 2001 9130xk20
This is a source reference. Confirm exact model applicability in the original material.