996 Turbo diagnostic manual — Turbo applicability only / PAGE 444
90-21Fault code 9132 · Terminal 61
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
911 Turbo (996) Instrument cluster K20 90
90-21Fault code 9132
Terminal 61
Diagnostic conditions
• Ignition on
Possible cause of fault
♦Open circuit in the wire between instrument cluster and genera-
tor (terminal 61)
♦Generator faulty
Affected terminals
Plug A, terminal 12
Diagnosis/troubleshooting
Work instruction Display OK If not OK
1 Visual inspection ♦Check plug on generator for ⇒ Step 2 Push on plug
contact and corrosion. → End
2 Check wire from genera- ♦Pull plug off the generator < 5Ω Repair wiring har-
tor to instrument cluster ⇒ Step 3 ness ♦Measure resistance between
for open circuit → End plug A on the instrument cluster
pin 12 and plug on generator pin
1 (L)
3 ♦Replace generator → End
9025 Fault code 9132 90-21 page 1
Printed in Germany – 8, 2001 9132xk20