996 Turbo diagnostic manual — Turbo applicability only / PAGE 533
91-12Fault code 6 · Sensor supply voltage < 6.7 V
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
911 Turbo (996) ParkAssist P02 91
91-12Fault code 6
Sensor supply voltage < 6.7 V
Diagnostic conditions
• Ignition on
• Reverse gear engaged
• Continuous fault tone emitted for 0.5 seconds after engaging
reverse gear
Possible cause of fault
♦Low vehicle voltage
♦Short circuit in supply leads to the control module
♦Faulty sensor
♦Faulty control module
Affected terminals
Terminals I/5 and I/7
Diagnosis/troubleshooting
Work instruction Display OK If not OK
1 Visual inspection ♦Check sensors for external dam- Replace sensor.
age. Step 2 → End
2 Check supply voltage of ♦Select Sensor supply voltage in Approx. 8 V
the sensors the Actual values menu item. → End Step 3
3 Check supply lead of the ♦Switch off ignition. Approx. 8 V
sensors Step 4 Step 5 ♦Pull off plugs on all sensors.
♦Engage reverse gear.
♦Switch on ignition.
♦Measure voltage on all sensor
plugs at pin 3 and ground
respectively.
♦Measure voltage on all sensor
plugs at pins 3 and 2 respec-
tively.
9101 Fault code 6 91-12 page 1
Printed in Germany – 42, 2003 6xxxxp02
This is a source reference. Confirm exact model applicability in the original material.