996 Turbo diagnostic manual — Turbo applicability only / PAGE 533

91-12Fault code 6 · Sensor supply voltage < 6.7 V

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 533
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

911 Turbo (996) ParkAssist P02 91 91-12Fault code 6 Sensor supply voltage < 6.7 V Diagnostic conditions • Ignition on • Reverse gear engaged • Continuous fault tone emitted for 0.5 seconds after engaging reverse gear Possible cause of fault ♦Low vehicle voltage ♦Short circuit in supply leads to the control module ♦Faulty sensor ♦Faulty control module Affected terminals Terminals I/5 and I/7 Diagnosis/troubleshooting Work instruction Display OK If not OK 1 Visual inspection ♦Check sensors for external dam- Replace sensor. age. Step 2 → End 2 Check supply voltage of ♦Select Sensor supply voltage in Approx. 8 V the sensors the Actual values menu item. → End Step 3 3 Check supply lead of the ♦Switch off ignition. Approx. 8 V sensors Step 4 Step 5 ♦Pull off plugs on all sensors. ♦Engage reverse gear. ♦Switch on ignition. ♦Measure voltage on all sensor plugs at pin 3 and ground respectively. ♦Measure voltage on all sensor plugs at pins 3 and 2 respec- tively. 9101 Fault code 6 91-12 page 1 Printed in Germany – 42, 2003 6xxxxp02

This is a source reference. Confirm exact model applicability in the original material.