996 Turbo diagnostic manual — Turbo applicability only / PAGE 562
Menu item Function · ♦Air conditioning with/without Under this menu item, the PCM2 GW corresponding to th
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
911 Turbo (996) PCM2/CDR23 91
Menu item Function
♦Air conditioning with/without Under this menu item, the PCM2 GW corresponding to the air conditioning
equipment can be coded.
♦9588 Connect and start the Porsche System Tester II and switch on the
ignition.
♦Select '911 Turbo (996)' in the Vehicle type menu and confirm with the
>> key.
♦Select 'PCM2' in the control modules selection and confirm with the >>
key.
♦Select 'PCM2 GW' in the PCM2 function selection and confirm with the
>> key.
♦Select 'Coding' in the PCM2 GW menu and confirm with the >> key.
♦Select 'Air conditioning with/without' in the PCM2 GW coding menu and
confirm with the >> key.
♦Select "Air conditioning with/without" corresponding to the equipment in
the Modify PCM2 GW coding menu item and confirm with the >> key.
♦Select "the relevant country coding" from the menu item that is displayed
and code it with the F8 key.
♦Tuner parameters Using this menu item, you can code the tuner parameters (country-specific
tuner setting) for the country of registration.
♦9588 Connect and start the Porsche System Tester II and switch on the
ignition.
♦Select '911 Turbo (996)' in the Vehicle type menu and confirm with the
>> key.
♦Select 'PCM2' in the Control units selection menu and confirm with the
>> key.
♦Select 'PCM2 GW' in the 911 Turbo (996) PCM2 function selection menu
and confirm with the >> key.
♦Select 'Coding' in the PCM2 GW function selection menu and confirm
with the >> key.
♦Select "Tuner parameter" in the PCM2 GW coding menu and confirm with
the >> key.
♦Select the 'Country code' corresponding to the country of registration
using the > key and code with the F8 key.
9101 Control unit function - gateway 91-63 page 5
Printed in Germany – 43, 2003 SgfGWlwl
This is a source reference. Confirm exact model applicability in the original material.