996 Turbo diagnostic manual — Turbo applicability only / PAGE 662
PCM2/CDR23 911 Turbo (996)91 · • Never start engine without securely connected battery.
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
PCM2/CDR23 911 Turbo (996)91
• Never start engine without securely connected battery.
• Never pull off or push on plug connections for the control
modules or other electronic components when the ignition
is switched on.
General information on the fault memory
Fault code setting conditions
Fault codes can be set in several circumstances, e.g.:
♦battery disconnected.
♦plug connections disconnected.
♦power failure.
In these circumstances, no fault is present in the system and the
fault memory must be erased.
Display '*' in the menu 'Control modules' and menu 'PCM2
MOST component check'.
Different required and actual installed components lists
When the 'automatic control module search' is complete, the follow-
ing display '*' appears in front of the control module description
'PCM2' in the 'Control modules' menu, as well as in the 'PCM2 MMI
function selection' in front of the entry 'MOST required installed
components list' if the 9588 Porsche System Tester ll establishes a
difference between the required and actual installed components
list and there is no fault code in one of the fault memories of the
MOST control modules.
If there is a fault code present in one of the MOST control modules,
the display '*' is only shown in the 'PCM2 MMI function selection' in
front of the line 'MOST required installed components list'.
If there is a display in the menu Control module, an existing fault
code has priority and a '#' is set.
Fault memory Info key F8
In order to be able to assess the fault exactly, the fault memory Info
key F8 must be pressed. This information should be saved using
the Save key F4 and printed out. If a fault code is stored with "not
present" status and no other problems are present, then the fault
memory must be erased.
91-85 page 2 9101 Introduction – external Harman amplifier
EINVSlwl Printed in Germany – 43, 2003
This is a source reference. Confirm exact model applicability in the original material.