PCM2/CDR23 911 Turbo (996)91
• Never start engine without securely connected battery.
• Never pull off or push on plug connections for the control
modules or other electronic components when the ignition
is switched on.
General information on the fault memory
Fault code setting conditions
Fault codes can be set in several circumstances, e.g.:
♦battery disconnected.
♦plug connections disconnected.
♦power failure.
In these circumstances, no fault is present in the system and the
fault memory must be erased.
Fault memory Info key F8
In order to be able to assess the fault exactly, the fault memory Info
key F8 must be pressed. This information should be saved using
the Save key F4 and printed out. If a fault code is stored with "not
present" status and no other problems are present, then the fault
memory must be erased.
Fault type - Frequency counter/Temperature/Voltage; Speed/Time of occurrence.
Supply voltage fault type The display shows which fault type has occurred:
♦Undervoltage '< 9 V'
♦Overvoltage ' > 16 V'
Open circuit in distribution line The value indicates the status of the MOST ring when the fault occurred.
♦Optically faulty
♦Electrically faulty
Frequency counter When a fault first occurs, a fault entry is made in the fault memory and the
counter is simultaneously set to 50.
If a fault is present, the counter is incremented by 1 for each "ignition on". The
maximum count is 255.
The counter is decremented if the fault is no longer present. The fault memory
is automatically erased when the counter reaches 0.
If the error occurs again when the counter is between 1 and 49, the counter is
reset to 50.
Temperature: The value indicates the temperature (temperature sensor in the gateway) at the
time the fault occurred. The temperature of the fibre optic transmitter is moni-
tored: max 85°C.
91-140 page 2 9101 CDR23 - Introduction
EINCRlwl Printed in Germany – 43, 2003