996 Turbo diagnostic manual — Turbo applicability only / PAGE 964
94-11Fault code 5 · 5 V supply for axle position sensors (angle sensors for
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
911 Turbo (996) Headlight beam adjustment HBA 01 94
94-11Fault code 5
5 V supply for axle position sensors (angle sensors for
HBA)
Diagnostic conditions
• Ignition on
• Terminal 58 on
Possible cause of fault
♦Short circuit to voltage/ground in the supply leads between the
control module and angle sensors for HBA
♦Angle sensor for HBA is faulty
♦The control module is faulty
Note!
The 5 V supply voltage for the sensors is ensured via pin 14 on the
HBA control module. A fault in this supply lead affects both angle
sensors. Moisture in the angle sensors plug can lead to a fault
entry.
Affected terminals
Terminals 14 and 17
9492 Fault code 5 94-11 page 1
Printed in Germany, 2001 5xxxlw01
This is a source reference. Confirm exact model applicability in the original material.