996 Turbo diagnostic manual — Turbo applicability only / PAGE 964

94-11Fault code 5 · 5 V supply for axle position sensors (angle sensors for

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 964
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

911 Turbo (996) Headlight beam adjustment HBA 01 94 94-11Fault code 5 5 V supply for axle position sensors (angle sensors for HBA) Diagnostic conditions • Ignition on • Terminal 58 on Possible cause of fault ♦Short circuit to voltage/ground in the supply leads between the control module and angle sensors for HBA ♦Angle sensor for HBA is faulty ♦The control module is faulty Note! The 5 V supply voltage for the sensors is ensured via pin 14 on the HBA control module. A fault in this supply lead affects both angle sensors. Moisture in the angle sensors plug can lead to a fault entry. Affected terminals Terminals 14 and 17 9492 Fault code 5 94-11 page 1 Printed in Germany, 2001 5xxxlw01