996 Turbo diagnostic manual — Turbo applicability only / PAGE 1011
Alarm system I 48 911 Turbo (996)96 · Work instruction Display O
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
Alarm system I 48 911 Turbo (996)96
Work instruction Display OK If not OK
4 Check operating points of ♦Measure resistance between Central locking ⇒ Step 5
central locking switch pins 4 and 1 on central locking switch not actuated → End
switch in "close" direction
∞ Ω
Central locking
switch actuated in
"close" direction
< 5 Ω
⇒ Step 6
5 ♦Replace central locking switch → End
6 ♦Replace control module → End
96-15 page 2 9601 Fault code 9
9xxxxi48 Printed in Germany – 4, 2001