996 Turbo diagnostic manual — Turbo applicability only / PAGE 1025

96-25Fault code 19 · Status lead, signal converter, short circuit to B+

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 1025
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

911 Turbo (996) Alarm system I 48 96 96-25Fault code 19 Status lead, signal converter, short circuit to B+ Diagnostic conditions • Terminal 86S switched on Possible cause of fault ♦Short circuit to voltage in wire between the alarm system control module and the signal converter Affected terminals Plug A, terminals 3 and 4 Diagnosis/troubleshooting Work instruction Display OK If not OK 1 Check wiring from signal ♦Switch off ignition ∞ Ω Repair wiring har- converter to control mod- ⇒ Step 2 ness ♦Pull plug A off the control mod- ule for short circuit to → End ule ground ♦Pull plug off the signal converter ♦Measure resistance between plug A on control module pin 4 and ground ♦Measure resistance between plug A on control module pin 3 and ground 2 Check wiring from signal ♦Switch off ignition 0 V Repair wiring har- converter to control mod- ⇒ Step 3 ness ♦Pull plug A off the control mod- ule for short circuit to B+ → End ule ♦Pull plug off the signal converter ♦Switch on ignition ♦Measure voltage between plug A on control module pin 4 and ground ♦Measure voltage between plug A on control module pin 3 and ground 9601 Fault code 19 96-25 page 1 Printed in Germany – 4, 2001 19xxxi48