996 Turbo diagnostic manual — Turbo applicability only / PAGE 1045
96-42Fault code 36 · Passenger compartment monitoring sensor, short cir-
Read extracted page text
OCR can contain errors. Check the original page image for exact wording, warnings and specifications.
911 Turbo (996) Alarm system I 48 96
96-42Fault code 36
Passenger compartment monitoring sensor, short cir-
cuit to B+ or faulty
Diagnostic conditions
• Alarm system activated
Possible cause of fault
♦Short circuit to voltage in the wiring between the alarm system
control module and the passenger compartment monitoring sen-
sor
♦Passenger compartment monitoring sensor faulty
Affected terminals
Plug A, terminals 8 and 24
Diagnosis/troubleshooting
Work instruction Display OK If not OK
1 Check supply voltage of ♦Switch off ignition > 11 V Check or repair wir-
the sensor ⇒ Step 2 ing harness ♦Pull off the plug on the passen-
→ End ger compartment monitoring
sensor
♦Measure voltage between the
plug on the passenger compart-
ment monitoring sensor pin 1
and pin 4
2 Check the wiring from ♦Pull plug A off the alarm system 0 V Repair wiring har-
passenger compartment control module ⇒ Step 3 ness
monitoring sensor to → End ♦Switch on ignition
alarm system control
♦Measure voltage between plug module for short circuit to
24 on alarm system pin 24 and B+
ground
♦Measure voltage between plug A
on alarm system pin 8 and
ground
3 ♦Replace passenger compartment monitoring sensor → End
9601 Fault code 36 96-42 page 1
Printed in Germany – 4, 2001 36xxxi48
This is a source reference. Confirm exact model applicability in the original material.