fullymatted.
Back to search
996 Turbo diagnostic manual — Turbo applicability only / PAGE 1045

96-42Fault code 36 · Passenger compartment monitoring sensor, short cir-

Add to repair workspace
Open repair workspace
Open full manual Original source
Original manual page 1045
Read extracted page text

OCR can contain errors. Check the original page image for exact wording, warnings and specifications.

911 Turbo (996) Alarm system I 48 96 96-42Fault code 36 Passenger compartment monitoring sensor, short cir- cuit to B+ or faulty Diagnostic conditions • Alarm system activated Possible cause of fault ♦Short circuit to voltage in the wiring between the alarm system control module and the passenger compartment monitoring sen- sor ♦Passenger compartment monitoring sensor faulty Affected terminals Plug A, terminals 8 and 24 Diagnosis/troubleshooting Work instruction Display OK If not OK 1 Check supply voltage of ♦Switch off ignition > 11 V Check or repair wir- the sensor ⇒ Step 2 ing harness ♦Pull off the plug on the passen- → End ger compartment monitoring sensor ♦Measure voltage between the plug on the passenger compart- ment monitoring sensor pin 1 and pin 4 2 Check the wiring from ♦Pull plug A off the alarm system 0 V Repair wiring har- passenger compartment control module ⇒ Step 3 ness monitoring sensor to → End ♦Switch on ignition alarm system control ♦Measure voltage between plug module for short circuit to 24 on alarm system pin 24 and B+ ground ♦Measure voltage between plug A on alarm system pin 8 and ground 3 ♦Replace passenger compartment monitoring sensor → End 9601 Fault code 36 96-42 page 1 Printed in Germany – 4, 2001 36xxxi48